StartMade Blog Episode 152 ·

The "1.5mm²" Power Strip Cords Got Too Hot to Touch
Power Cord Wire Gauge & Copper Verification Guide - Why Power Cords and Power Strips That Passed Inspection Overheat and Soften in Use, Marked Cross-Section vs Actual Size, Pure Copper vs CCA (Copper-Clad Aluminum) and Recycled Copper, Checks Such as Conductor Resistance, Strand Count and Diameter, Insulation Thickness, Scraping and Weight Compared, Approximate Criteria, Gaps in Factory Reports and Jacket Printing, Supplier Substitution Such as Copper Samples Only, Undersized Conductors, Fewer Strands and Thinner Insulation, Spec Sheet Items, Stage-by-Stage Checks and a Checklist

Hello, this is StartMade.

A household goods seller imported 5,000 power strips with individual switches from a factory in Cixi (慈溪), Zhejiang. They were rated 16A, the cord jacket was clearly printed "3×1.5mm²," and the pre-shipment inspection passed them on appearance, continuity, switch function and packaging. The factory said the cords were "national standard (国标) pure copper" and even attached a material test report.

The trouble started when winter arrived. Customers who plugged in electric heaters and fan heaters began reporting that "the cord is too hot to touch" and "the jacket near the plug has gone soft." Close to twenty complaints came in within two weeks. When the seller stripped the cords from remaining stock, the copper-colored strands were silver inside. It was CCA wire: aluminum with a thin copper coating. The actual cross-section, calculated from the strand diameter, was about 1.0mm², and the conductor resistance per meter was more than double the limit for 1.5mm² pure copper. Higher resistance means much more heat at the same current. A few hours with a 2kW heater was enough for the cords to overheat.

What makes wire problems tricky is that nothing looks different from the outside. CCA wire and undersized wire look exactly like genuine pure copper once they are jacketed, and they pass continuity checks without trouble. The difference shows up as heat only after high current has flowed for hours. This article covers how to check wire size and material, approximate criteria, the substitutions factories commonly use, and how to add wire checks to your spec sheet and inspection checklist, all from a practical point of view.

The "1.5mm²" printed on the jacket and a material test report are not enough. Set conductor material, cross-section, strand construction and a maximum conductor resistance in numbers in your spec sheet, and cut and measure the cords of products you pick yourself from the production lot. That is how you prevent overheating claims and safety incidents.

Note This article is practical information based on common practice at Chinese wire and power cord factories as of November 2026, criteria widely used in the industry, standards such as IEC 60228 and GB/T 3956 (conductors of cables) and IEC 60227 and GB/T 5023 (PVC insulated cables), and Korea's electrical product safety certification (KC) system. Required criteria and test conditions vary with product rating and use, whether certification applies, and sales channel requirements, so set actual criteria for your product with input from a certification body or test lab. Figures and amounts in this article are examples to aid understanding.

1. Why Cords Overheat and Insulation Melts

When current flows through a wire, conductor resistance turns some of it into heat. Heat equals current squared times resistance, so at the same 16A a wire with double the resistance produces double the heat. Resistance is set by the conductor's material and cross-section. Use a material that conducts worse than copper, or shrink the cross-section, and resistance goes up.

Aluminum has about 1.6 times the resistance of copper. CCA wire is an aluminum core with a thin copper coating, so it looks like copper but behaves electrically much like aluminum. Use a thinner wire than marked on top of that and resistance climbs further. If a wire marked 1.5mm² is really 1.0mm², that alone raises resistance by 1.5 times. Add CCA and it ends up well over double that of the genuine product.

A high-resistance cord gives no sign of trouble when it powers a phone charger or a desk lamp. Plug in something that draws high current for a long time, such as an electric heater, air fryer or electric cooktop, and the cord heats up. The insulation softens and then melts, which can lead to short circuits or fire.

Wire size and material problems usually come from five causes.

We covered importing home appliances in general in Episode 75 and dielectric strength testing in Episode 138. This article focuses on checking that the conductor inside the cord is what the marking says.


2. Checking Methods — From Jacket Printing to Conductor Resistance

If you only say "please check the wire spec," the factory will often send a photo of the jacket printing or the wire supplier's report and leave it there. Each method tells you something different, so decide first how you will check.

MethodHow it worksWhat it tells youLimits
Jacket printing checkRead the size, maker and certification marks printed on the sheathMarked size, wire supplierAnyone can print anything; unrelated to the actual conductor
Scrape and cut visual checkScrape or cut a strand and look at the color insideScreens out CCA (silver core) and CCS (sticks to a magnet)Cannot catch recycled copper or undersizing
Strand count and diameterCount strands and measure diameter with a micrometer to calculate cross-sectionEstimated actual cross-sectionMeasurement error; says nothing about material
Conductor resistance (导体电阻)Four-wire measurement on a set length of conductor, converted to a 20°C per-km value (IEC 60228, GB/T 3956)Real electrical performance combining material and cross-sectionNeeds a low-resistance meter; temperature correction is essential
Weight and density comparisonCompare the weight of 1m of stripped conductor with a genuine oneFlags suspected CCA or undersizingNot precise enough for a final call
Insulation thicknessCut a cross-section and measure minimum insulation and sheath thickness (IEC 60227)Insulation safety marginAccurate with a microscope or profile projector

Jacket printing is not evidence

The most common mistake is to see "3×1.5mm²" and a certification mark on the sheath and stop there. Jacket printing is just ink-jetted text added during extrusion and has nothing to do with what is inside. Plenty of non-standard wire carries national standard sizes and well-known wire makers' names. Treat the printing as a starting point only, and always cut and measure.

Conductor resistance is the final test

Measuring conductor resistance is more reliable than checking material and size one by one. CCA, thin wire and recycled copper all end up showing as higher resistance. Cut at least 1m of conductor, take a four-wire measurement with a low-resistance meter, record the temperature and convert to 20°C. If the resistance is within the standard limit, the wire passes electrically, whatever was done to its material or size.


3. What Criteria to Set

Maximum conductor resistance by cross-section is set in IEC 60228 and in GB/T 3956, which carries the same content. Approximate values at 20°C for flexible stranded conductors (Class 5) used in power cords are below. Set actual criteria with input from a test lab based on cable type, rating and certification requirements.

Marked cross-sectionMax conductor resistance (20°C, plain copper, stranded)Typical use
0.75mm²About 26.0 Ω/km or lessSmall appliances, lighting cords
1.0mm²About 19.5 Ω/km or less10A power cords
1.5mm²About 13.3 Ω/km or less16A power strips and extension cords
2.5mm²About 7.98 Ω/km or lessHeavy-duty extension cords, industrial use

Read the table backwards and it works as a screening tool too. If a wire marked 1.5mm² measures around 19 Ω/km, it is really 1.0mm² class; above 20 Ω/km it is almost always undersized or CCA. For insulation, IEC 60227-type PVC cords of 0.75-1.5mm² specify an average insulation thickness of about 0.6-0.7mm, so cut a cross-section and look for visibly thin spots as well.


4. Why You Should Not Take Factory Reports and Certificates at Face Value

When you ask for evidence on the wire, the factory usually sends the wire supplier's outgoing test report or a copy of a KC or CCC certificate. These documents have gaps.

GapWhat happensWhat to check
Certification sample vs productionCertification covers the submitted sample; the certificate stays the same even if the wire changes in productionCompare the wire supplier and size in the certificate with the actual product
No link between report and lotA wire supplier's report covers one lot and does not prove that wire went into your productLink incoming wire lot numbers to the production order
"Pass" with no measured valuesOnly "合格" is written, with no measured resistance or temperatureMeasured values, length, temperature, equipment
Separately prepared samplesGenuine wire cut separately and sent for testingPick finished products at random, cut and measure
"It's 国标线 (national standard wire)" is not enough Even if the factory says "national standard pure copper," you still need to confirm which wire maker and which spec it is, and what the measured conductor resistance is. On factory floors, "national standard" is used loosely to mean "decent enough wire." Ask for the wire maker's name and spec, the incoming lot number and measured conductor resistance together.

5. Common Supplier Substitutions

Copper makes up a large share of a power cord's cost, so when copper prices rise or price pressure is heavy, the wire is the first place factories cut. Here are the patterns we have actually run into in consultations.

TypeHow it is doneHow to prevent it
Copper samples onlyApproval and certification samples use genuine copper; production uses CCA or non-standard wireRecord approval sample resistance; compare production at the same length
Undersized conductorPrinted 1.5mm² with a 1.0-1.25mm² equivalent conductor; outer diameter made up with insulationCalculate from strand count and diameter; measure resistance
Mixing in CCA or CCSCopper-plated aluminum or steel cores, sometimes only some strandsScrape test, magnet, conductor resistance
Recycled copperImpure recycled copper that looks like copper but has high resistanceConductor resistance (scraping will not catch it)
Thinner insulationReduced insulation and sheath thickness, recycled PVCCross-section thickness measurement, dielectric strength test
Poor internal plug connectionsGenuine wire but poor crimping or soldering in the plug or socketsTeardown, temperature check under load

The most common pattern is genuine copper in the samples and different wire in production. The product looks fine and passes continuity and dielectric tests, so unless the inspector cuts the cord, there is no way to notice. Simply cutting 1m from the cord of a randomly picked product and measuring its resistance catches a large share of cases. We explained the same principle of covert material substitution for plastics in Episode 125 and stainless steel in Episode 150.


6. The Damage Wire Defects Leave Behind

Wire defects do not show at shipment and only appear when customers draw high current, but the damage spreads far beyond the product's price.

See Episode 53 for product liability and recalls and Episode 10 for product certification.


7. What to Put in the Spec Sheet

A single line like "3×1.5mm² pure copper wire" gets read differently by every factory. Put the items below in a table and attach it to your spec sheet. See Episode 59 for how to write a spec sheet.

ItemExample
Cable type and sizeH05VV-F 3G1.5mm² (or the identical spec listed in the certificate), length 1.5m
Conductor materialOxygen-free or electrolytic pure copper, stranded; no CCA, CCS or recycled copper
Strand constructione.g. for 1.5mm², about 75 or more strands of 0.16mm (match the wire maker's spec)
Conductor resistance13.3 Ω/km or less at 20°C (IEC 60228 / GB/T 3956 Class 5)
Insulation thicknessAverage and minimum insulation and sheath thickness at or above IEC 60227
Wire supplierApproved wire maker and spec fixed; prior written approval for any change
DocumentsIncoming wire lot numbers, measured conductor resistance per lot (length, temperature, equipment), cross-section photos

Writing the maximum conductor resistance as a number may seem fussy, but it does the most work. Words like "pure copper" and "1.5mm²" leave room for interpretation, while a resistance value gives a clear answer with one meter. See Episode 119 for how to handle changes in wire supplier or spec.


8. How to Add Wire Checks to Your QC Checklist

Sample stage

When the approval samples arrive, sacrifice one cord: cut 1m and record conductor resistance, strand count, strand diameter and insulation thickness with cross-section photos. Run the remaining samples near rated current for two to three hours and measure cord and plug temperature. These records become the baseline for comparing production units.

Production stage

During production, get the lot number, the wire maker's report and the factory's own conductor resistance measurement when wire arrives at the factory. If the results show the same number every time with no measurement temperature, start by asking whether anyone actually measured. If possible, also get photos of the labels on the incoming wire reels. See Episode 102 for production tracking.

Pre-shipment inspection stage

The inspector picks packed products personally, cuts the cord, scrapes the strands to check the color inside, tries a magnet and measures 1m conductor resistance. If bringing a low-resistance meter is impractical, seal randomly picked samples and send them to a third-party lab. Also check that the jacket printing and plug markings match the certificate. See Episode 100 for pre-shipment inspection and Episode 47 for using third-party inspection.

Example wire control conditions Power cord shall be pure copper stranded 3G1.5mm² with conductor resistance of 13.3 Ω/km or less at 20°C. For each lot, cut 1m from the cords of 5 randomly picked products, measure conductor resistance by the four-wire method and record the temperature, scrape strands to check for CCA and test with a magnet, and measure minimum insulation thickness; all samples must pass. Compare with approval sample measurements. If any fails, increase the sample size from the same lot and retest; if it still fails, hold that lot's shipment and rework it with replacement wire. Figures are examples; actual conditions must match product rating and certification requirements.

9. Sample Wording to Send the Factory

Putting the wording below in your purchase order or spec sheet takes the choice of wire out of the factory's hands and makes it easier to assign responsibility if overheating claims arise.

"本产品电源线须使用纯铜多股导体H05VV-F 3G1.5mm²(与认证报告所列规格及线材供应商一致),严禁使用铜包铝(CCA)、铜包钢(CCS)、再生铜或非标线。导体电阻须符合GB/T 3956或IEC 60228第5类导体要求,20℃换算值不得超过13.3Ω/km;绝缘及护套厚度须符合IEC 60227要求。未经我方书面同意不得更换线材供应商、线材规格或生产工厂。每批须提交线材入库批号、线材供应商出厂报告,以及注明测量长度、温度和设备的导体电阻实测记录和截面照片。检测样品由我方验货员从成品中随机抽取并剪线测量。如有争议,以第三方实验室按GB/T 3048.4或IEC 60228测得的导体电阻为准。如有不合格,须加抽复测;复测仍不合格的批次暂停出货,并更换合格线材返工。"
(The power cord of this product shall use pure copper stranded conductor H05VV-F 3G1.5mm² (identical in spec and wire supplier to the certification report); copper-clad aluminum (CCA), copper-clad steel (CCS), recycled copper and non-standard wire are prohibited. Conductor resistance shall meet GB/T 3956 or IEC 60228 Class 5 requirements and shall not exceed 13.3 Ω/km at 20°C; insulation and sheath thickness shall meet IEC 60227. The wire supplier, wire spec and production factory may not be changed without our written consent. Each lot shall be accompanied by the incoming wire lot number, the wire supplier's outgoing report, and measured conductor resistance records stating length, temperature and equipment, with cross-section photos. Test samples shall be picked at random from finished products by our inspector and the cords cut for measurement. In case of dispute, conductor resistance measured by a third-party lab under GB/T 3048.4 or IEC 60228 shall prevail. If any sample fails, additional samples shall be drawn and retested; lots that still fail shall be held from shipment and reworked with conforming wire.)


10. Three Real Cases

These are anonymized versions of patterns we see often in consultations. Amounts and figures are examples.

Case 1 — 16A power strips with individual switches

This is the case from the start of the article. When the seller confronted the factory with the measurements, the factory blamed its wire supplier for sending something different. It turned out the wire supplier used for the certification sample differed from the one used in production; the factory had switched to a supplier 30% cheaper without saying so. Sales suspension, voluntary recall, replacements and certification-related work added up to a loss of about 48 million won, and the factory covered only part of it. From the next order, the wire maker and maximum conductor resistance are in the spec sheet, and cords are cut and measured at pre-shipment inspection.

Case 2 — Electric heating mat power cords

A winter goods brand imported 2,000 electric heating mats whose cords were printed "2×0.75mm²" and looked copper-colored all the way through when scraped. Yet complaints that "the cord connection gets warm" kept coming, and a lab measured conductor resistance at 39 Ω/km, 1.5 times the limit. The color was copper, but the wire was impure recycled copper with strands thinner than standard. Scraping and a magnet could not have caught it, so the brand now requires measured conductor resistance for every lot.

Case 3 — USB fast-charging cables

A phone accessories company sold 10,000 USB-C cables as "100W fast charging," and reviews saying "charging is slow and the cable gets hot" kept piling up. Cutting the cables open showed CCA power wires thinner than the marked spec. Under high current the voltage drop was large enough that chargers cut their output. Data transfer and short charging tests worked fine, which is how the cables passed inspection. The company has since added power wire spec and resistance to the spec sheet and a check that charges at rated current for a set time while measuring cable temperature.


11. Common Mistakes


12. Wire Gauge and Material Control Checklist

Specification stage

Sample and production stage

Pre-shipment inspection stage


Final Thoughts - Check Resistance, Not Printing

When power cords leave the factory, genuine copper and CCA look equally neat and smooth. The difference only shows up as heat after a customer has run a heater for a few hours. Writing a maximum conductor resistance in the spec sheet and cutting 1m of cord per lot to measure it does not cost much. Put the price of one low-resistance meter next to tens of millions of won in recall and certification costs, and it is clear which is cheaper.

There is something you can do right now. Ask the factory currently in production to send the name of the wire maker it is using, the incoming lot number, measured conductor resistance with temperature, and photos of the wire cross-section. If the reply is a single line saying "it's national standard pure copper," make a wire control conditions sheet and send it before your next order.

StartMade supports you on the ground with spec sheets that set wire spec and conductor resistance criteria, wire measurement records for approval samples, checks on incoming wire during production, and pre-shipment inspections where cords are cut and measured. If you have already received overheating claims, we start by measuring the wire in your remaining stock; if you are preparing a new product, we start with wire spec and supplier selection.

Is the Wire in Your Product What the Label Says?

From setting wire spec and conductor resistance criteria to incoming checks, cut-and-measure tests and pre-shipment inspection
We check on the ground before overheating claims arrive

Phone   010-9980-9959
Email   deanpark@greenfrogseoul.com
KakaoTalk   pf.kakao.com/_XkfuX
Website   www.startmade.co.kr

Frequently Asked Questions

How can you tell if a wire is CCA (copper-clad aluminum)?
Strip the insulation and scrape or cut the end of a strand to look at the cross-section. If it is copper-colored outside but silver inside, it is CCA, an aluminum core with a thin copper coating. Being noticeably lighter than the same length of pure copper wire is another clue. Recycled copper and undersized wire will not show up this way, though, so measuring conductor resistance is the reliable final check.
How do you check whether a wire is thinner than marked?
The numbers printed on the jacket prove nothing, so you have to measure. Counting the strands and measuring strand diameter with a micrometer gives a rough figure for the actual cross-section. The more reliable way is to cut at least 1m, measure conductor resistance, convert it to 20°C and compare it with the standard limit. For 1.5mm² stranded pure copper, it should come in at 13.3 Ω/km or less.
Why do power strip cords get hot?
Usually because the conductor resistance is too high, so a lot of heat is produced when current flows. Wire that is thinner than marked, or CCA or recycled copper used in place of pure copper, raises resistance, and the cord heats up when you plug in something like an electric heater that draws high current for a long time. Loose crimped connections inside the plug or sockets can also make those spots run hot.